To read this content please select one of the options below:

A tensioning control method for stay cables with super large tonnage cable force

Lifeng Wang (School of Civil Engineering and Transportation, Northeast Forestry University, Harbin, China)
Yi Zhang (School of Civil Engineering and Transportation, Northeast Forestry University, Harbin, China)
Ziwang Xiao (School of Civil Engineering and Transportation, Northeast Forestry University, Harbin, China)
Long Liu (School of Civil Engineering and Transportation, Northeast Forestry University, Harbin, China) (Anyang Institute of Technology, Anyang, China)

International Journal of Structural Integrity

ISSN: 1757-9864

Article publication date: 30 April 2024

Issue publication date: 13 May 2024

12

Abstract

Purpose

Effectively solving the large tonnage cable in the construction process due to the tensioning method of the inclined cable often appears in the overall cable force and the design value of the deviation is large, cable internal strand force is not uniform, the main girder stress exceeds the limit of the problem affecting the safety of the structure.

Design/methodology/approach

In this study, the finite element method and theoretical analysis method are utilized to propose a construction control method of tensioning the whole bunch of diagonal cables in two parts according to the deformation coordination relationship between the main girder and the diagonal cables. This methodology was implemented during the actual construction of the PAIRA Bridge in Bangladesh.

Findings

Tests conducted on cable-stayed bridges using this controlled tensioning method demonstrate that the measured cable strength of a single strand exhibits an error of less than 0.15% compared to the design target cable strength. The deviation between the measured and designed cable forces ranges from 0.16% to 0.27%. Furthermore, no tensile stress is observed in both the top plate and bottom plate of the root section of the main girder, indicating a state of full-section compression throughout the entire construction process.

Originality/value

Through the comparison with the test value, it can be proved that the whole bunch of diagonal cable tensioned in two parts of the construction control method proposed in this paper can make the internal strand force more uniform, to meet the precision requirements of the site construction, to protect the safety of the bridge construction process. The method proposed in this paper is highly accurate, easy to calculate, and has a high value of popularization and application.

Keywords

Acknowledgements

This study is supported by three key funds: The Key Research and Development Program of Heilongjiang Province, China (JD22A012); The Key Research and Development Plan Guidance Program of Heilongjiang Province, China (GZ20230065, GZ20210206); Science and Technology Project of Department of Transportation of Heilongjiang Province (HJK 2023B001).

Citation

Wang, L., Zhang, Y., Xiao, Z. and Liu, L. (2024), "A tensioning control method for stay cables with super large tonnage cable force", International Journal of Structural Integrity, Vol. 15 No. 3, pp. 613-630. https://doi.org/10.1108/IJSI-12-2023-0149

Publisher

:

Emerald Publishing Limited

Copyright © 2024, Emerald Publishing Limited

Related articles