Fabrication of vibration sensors using precursor molar concentration varied ZnO nanostructures grown by refresh hydrothermal method
ISSN: 0305-6120
Article publication date: 9 September 2021
Issue publication date: 5 April 2023
Abstract
Purpose
Various approaches have been made to alter the vibration sensing properties of zinc oxide (ZnO) films to achieve high sensitivity. This paper aims to report the experimental study of the fabrication of precursor molar ratio concentration varied ZnO nanostructures grown on rigid substrates using the refresh hydrothermal method. The effect of these fabricated ZnO nanostructures-based vibration sensors was experimentally investigated using a vibration sensing setup.
Design/methodology/approach
ZnO nanostructures have been grown using low temperature assisted refresh hydrothermal method with different precursor molar concentrations 0.025 M (R1), 0.075 M (R2) and 0.125 M (R3). Poly 3,4-ethylenedioxythiophene polystyrene sulfonate, a p-type material is spun coated on the grown ZnO nanostructures. Structural analysis reveals the increased intensity of the (002) plane and better c-axis orientation of the R2 and R3 sample comparatively. Morphological examination shows the changes in the grown nanostructures upon increasing the precursor molar concentration. The optical band gap value decreases from 3.11 eV to 3.08 eV as the precursor molar concentration is increased. Photoconductivity study confirms the formation of a p-n junction with less turn-on voltage for all the fabricated devices. A less internal resistance of 0.37 kΩ was obtained from Nyquist analysis for R2 compared with the other two fabricated samples. Vibration testing experimentation showed an improved output voltage of the R2 sample (2.61 V at 9 Hz resonant frequency and 2.90 V for 1 g acceleration) comparatively. This also gave an increased sensitivity of 4.68 V/g confirming its better performance when compared to the other fabricated two samples.
Findings
Photoconductivity study confirms the formation of a p-n junction with less turn-on voltage for all the fabricated devices. A less internal resistance of 0.37 kΩ was calculated from the Nyquist plot. Vibration testing experimentation proves an increased sensitivity of 4.68 V/g confirming its better performance when compared to the other fabricated two samples.
Originality/value
Vibration testing experimentation proves an increased sensitivity of 4.68 V/g for R2 confirming its better performance when compared to the other fabricated two samples.
Keywords
Citation
Gunasekaran, I., Rajamanickam, G., Narendiran, S., Perumalsamy, R., Ramany, K. and Sankararajan, R. (2023), "Fabrication of vibration sensors using precursor molar concentration varied ZnO nanostructures grown by refresh hydrothermal method", Circuit World, Vol. 49 No. 2, pp. 192-201. https://doi.org/10.1108/CW-08-2020-0183
Publisher
:Emerald Publishing Limited
Copyright © 2021, Emerald Publishing Limited