Abstract

Purpose

This paper aims to present an analytical method, which combines the complex permeance (CP) and the superposition concept, to predict the air-gap magnetic field distribution in surface-mounted permanent-magnet (SMPM) machines with eccentric air-gap.

Design/methodology/approach

The superposition concept is used twice; first, to predict the magnetic field distribution in slot-less machine with eccentric air-gap, the machine is divided into a number of sections. Then, for each section, an equivalent air-gap length is determined, and the magnetic field distribution is predicted as a concentric machine model. The air-gap field in the slot-less machine with eccentricity can be combined from these concentric models. Second, the superposition concept is used to find the CP under eccentricity fault. At this end, the original machine is divided into a number of sections which may be different from the one for slot-less magnetic field prediction, and for each section, the CP is obtained by equivalent air-gap length of that section. Finally, the air-gap magnetic field distribution is predicted by multiplying the slot-less magnetic field distribution and the obtained CP.

Findings

The radial and tangential components of the air-gap magnetic flux density are obtained using the proposed method analytically. The finite element analysis is used to validate the proposed method results, showing good agreements with the analytical results.

Originality/value

This paper addresses the eccentricity fault impact upon the air-gap magnetic field distribution of SMPM machines. This is done by a combined analysis of the complex permeance (CP) method and the superposition concept. This contrasts to previous studies which have instead focused on the subdomain method.

Keywords

Citation

Faiz, J., Hassanzadeh, M. and Kiyoumarsi, A. (2019), "Analytical calculation of magnetic field in surface-mounted permanent-magnet machines with air-gap eccentricity", COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, Vol. 38 No. 2, pp. 893-914. https://doi.org/10.1108/COMPEL-07-2018-0284