To read this content please select one of the options below:

Analytical study and simulation of a transformer-less photovoltaic grid-connected inverter with a delta-type tri-direction clamping cell for leakage current elimination

Tohid Jalilzadeh (Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran)
Mehrdad Tarafdar Hagh (Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran)
Mehran Sabahi (Faculty of Power Engineering, University of Tabriz, Tabriz, Iran)

Abstract

Purpose

This paper aims to propose a new transformer-less inverter structure to reduce the common-mode leakage current in grid-connected photovoltaic (PV) systems.

Design/methodology/approach

The proposed circuit structure is the same as the conventional full-bridge inverter with three additional power switches in a triangular structure. These three power switches are between the bridge and the output filter, and they mitigate the common-mode leakage current flowing toward the PV panels’ capacitors. The common-mode leakage current mitigation is done through the three-direction clamping cell (TDCC) concept. By clamping the common-mode voltage to the middle voltage of the DC-link capacitors, the leakage current and the total harmonic distortion (THD) of the injected current to the grid is effectively reduced. Therefore, the efficiency is improved.

Findings

The switching modes and the control method are introduced. A comparison is carried out between the proposed structure and other solutions in the literature. The proposed topology and its respective control method are simulated by PSCAD/EMTDC software. The simulation results validate the advantages of the presented structure such as clamping the common-mode voltage and reducing leakage current and THD of injected current to the grid.

Originality/value

Presenting a single phase-improved inverter structure with low-leakage current for grid-connected PV power systems represents a significant original contribution to this work. The proposed structure can inject a sinusoidal current with low THD to the AC grid, and the power factor is unity on the AC side. In the half positive cycle, one of the switches in the TDCC is turned off under zero current. Besides, one of the other switches in TDCC is turned on with zero voltage and, therefore, its turn-on switching losses are zero. The efficiency of the proposed topology is high because of the reduction of leakage current and power losses. Accordingly, the presented topology can be a good solution to the leakage current elimination.

Keywords

Citation

Jalilzadeh, T., Tarafdar Hagh, M. and Sabahi, M. (2018), "Analytical study and simulation of a transformer-less photovoltaic grid-connected inverter with a delta-type tri-direction clamping cell for leakage current elimination", COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, Vol. 37 No. 2, pp. 814-831. https://doi.org/10.1108/COMPEL-03-2017-0114

Publisher

:

Emerald Publishing Limited

Copyright © 2018, Emerald Publishing Limited

Related articles